PCA-4125

Power Communications Analyzer

Technical Specifications

  • General

    Size & Weight 12"x 9"x 1.75"" (310mm x 225mm x 45mm)
    5lbs (2.3Kg)
    Display Size & Type 5.7" (150mm)
    1/4 VGA Color
    Display Resolution 6 digit Frequency
    5 digit Voltage
    4 digit dBm
    Internal Memory 1 GB (Up to 1000 test set-ups, readings, or sweep results)
    Sweep Steps Up to 2000 steps
    Data Ports USB, RS232, LAN
    External Power Source 9 to 18V @ 3A
    1A @ 12V + charge current
    AC Adapter or 12VDC from car/external batteries
    Battery Type 3 x Lithium Polymer
    Battery Life Approximately 2 Hours
    Temperature Range -5 to +50 C
  • Selective Level Meter

    Frequency Range 5Hz to 5MHz
    Frequency Accuracy ±5ppm over all temperature range
    Magnitude Accuracy ±0.05% range, ±0.05% reading, ±1%/MH
    Inputs (Unbalanced) Type & Connection Differentially isolated & isolated BNC
    Bandwidth Frequency Range Settings 1Hz, 3Hz, 25Hz, 100Hz, 1.95K, 3.1K & wideband
    Frequency Setting All frequencies to 6 digit resolution
    Frequency Acquisition Single and 3 stage frequency acquisition
    Level Meter Accuracy ±0.01dB
    High Voltage Input
    Max Input ±300V Peak
    Input Impedance 1MΩ ±5% // 30p
    50Ω Input
    Max Input 18W (30V rms)
    Input Impedance 50Ω ±1% // 30pf
    75Ω Input (Option)
    Max Input 18W (37V rms)
    Input Impedance 75Ω ±1% // 30pf
    Low Level Input
    Max Input ±10V Peak
    Input Impedance 50Ω ±1% // 30pf
    75Ω ±1% // 30pf
    600Ω ±1% // 30pf
    1MΩ ±5% // 30p
    Input (Balanced)
    Max Input ±10V Peak
    Input Impedance 50Ω ±1% // 30pf
    75Ω ±1% // 30pf
    600Ω ±1% // 30pf
    1MΩ ±5% // 30p
    Input Type Differential
    Input Connection 3 x 4mm Connectors - Positive, Negative, & Ground
    Second Input
    Channel 2(CH2) ±10V Peak 1MΩ ±5% // 30pf
  • Signal Generator

    Generator Type Direct Digital Synthesis (DDS)
    Single Frequency or Sweep
    Generator Waveforms Sinewave, Square, Triangle, White Noise
    Frequency Accuracy ±5ppm over all temperature range
    High Level Output
    Frequency Range 10KHz to 5MHz
    Output Level 2W into 50Ω (10V rms)
    Output Impedance 50Ω ±2%
    75Ω ±2% (Option)
    Magnitude Accuracy ±2% 10dBm to 30dBm (50Ω), 100kHz to 1MHz
    ±3% 10dBm to 30dBm, 50kHz to 5MHz
    ±5% <10dBm or >30dBm, <50kHz
    Lo Level Output
    Frequency Range 5Hz to 5Mhz
    Output Level 5V rms into High Impedance
    Output Impedance 50Ω ±2% max + 18dBm
    75Ω ±2% max +16dBm
    600Ω ±2% max +7dBm
    Magnitude Accuracy ±1% from -10dBm to 20dBm to 1MHz
    ±2% from -20dBm to 5MHz
    ±3% from -30dBm to 5MHz
    ±5% from -40dBm to 1MHz
    ±10% from -40dBm to 5MHz
    Frequency Shift Delay Timer 0 to 1s (1ms steps)
  • Impedance Meter

    Impedance Range 100mΩ to 100KΩ
    Accuracy ±0.2% +2%/MHz
    Frequency Range 5Hz to 5MHz
    Features LCR Measurements (Inductance, Capacitance, Resistance, Tan delta QF)
    Lead compensation (Zero lead function)
    Impedance versus frequency curve
  • VSWR Meter

    Accuracy 1% of reading from 5Hz up to 1MHz
    5% of reading above 1MHz to 5MHz for power measurements (forward & reflected) at VSWR=3
    Features Forward Power
    Reflected Power
    % Reflected Power
    Frequency under test visible on one screen
  • Frequency Response Analyzer

    Frequency Range 5Hz to 5MHz
    Gain Accuracy dB 0.02dB < 1KHz
    0.05dB < 10KHz
    0.1dB + 0.001dB/KHz
    Phase Accuracy 0.02° < 10KHz
    0.02° + 0.003°/KHz
  • Oscilloscope

    Sample Rate 5 Msamples/sec
    Timebase 5µs/div to 5s/div
    Trigger Auto, Normal, or Single shot
    Pretrigger None, 25%, 50%, 75%
    Input Ranges As Selective Level Meter
    Second Input (CH2) ±10V Peak 1MΩ ±5% // 30pf